Service difficulty report · Meter · Dhav DHC8311

Difficulty date
January 22, 2009
Submitted
March 5, 2009
Operation
General aviation
Make and model
Dhav DHC8311
Aircraft time
34,245 hours
Engine
Pwa PW123
Part
Meter
Part number
67003008010
Condition
Failed
Location
A/C Power
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PILOT REPORTED, AC POWER METER CIRCUIT BREAKER POPPING. RECTIFICATION AC POWER METER REPLACED, CHECKED SERVICEABLE. AC POWER METER SENT TO VENDOR FOR REPAIR. WILL UPDATE SDR AT RECEIVING OF STRIP REPORT. UPDATE, FEB 10 2009 STRIP REPORT FROM AVIONICS SHOP STATEMENT- "INSPECT T/S FOUND INPUT DC RF FILTER SHORTED TO CASE GRD. REPAIR ALL THREE RF FILTERS ON DC POWER INPUT LINES, ASSEMBLE AND TEST TO MAN SPEC".