What was found
(CAN) WHILE CARRYING OUT A ROUTINE INSP OF THE ACFT, A CRACK WAS NOTICED IN THE AFT FRAME MEMBER OF THE RT FWD EMERGENCY EXIT SURROUND AT THE LWR CORNER (STN X264.1 RHS). THE FRAME MEMBER (P/N 85320534-103) WAS CRACKED FROM THE LIGHTENING HOLE TO THE INNER SURFACE AT STRINGER 22R. A TEMPORARY REPAIR IAW RD8-53-2823 WAS CARRIED OUT. WHILE REMOVING THE SIDEWALL PANELS TO GAIN ACCESS FOR THIS REPAIR, THE NEXT FRAME AFT (STN X270.5) WAS ALSO FOUND CRACKED AT STRINGER 22. THIS FRAME (P/N 85320220-105) WAS REPLACED WITH A -111 AT THE EXISTING FACTORY SPLICES IAW THE REQUIREMENTS OF THE SRM. DURING REMOVAL OF THE SEAT TRACK FOR ACCESS TO REPAIR THE FRAME AT X270.5 A THIRD FRAME WAS FOUND CRACKED AT STN X312.35. THE FRAME (P/N 85320094-107) WAS PERMANENTLY REPAIRED BY SPLICING IN A NEW SECTION FROM STRINGER 20 TO 27 IAW RD8-53-10572.