Service difficulty report · Circuit Breaker · Cndair CL6002D24

Difficulty date
April 25, 2009
Submitted
June 16, 2009
Operation
General aviation
Make and model
Cndair CL6002D24
Engine
Ge CF348C1
Part
Circuit Breaker
Part number
MS220733
Condition
Failed
Part time
199 hours
Stage of operation
TX
How discovered
O
Nature of condition
B, H
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) NR 2 ENG STARTED NORMALLY, DURING NR 1 START, EXPERIENCED A ENG HOT ICON WITH FADEC ABORT OF START. LOST AC ELECTRICAL POWER. NR 2 ENG & APU SHUTDOWN. ACFT TOWED BACK TO GATE. ACFT POWER SHUTDOWN. CREW REPORTED SYNOPTIC PAGE INDICATED AC BUSS 1 FAULTED. CB-N2 POPPED. F/A OBSERVED A FAINT ELECTRICAL ODOR IN CABIN, SAME ODOR EVIDENT IN COCKPIT. NR 2 CIRCUIT BREAKER RESET WITH EXT AC POWER. APU & NR 2 ENG STARTED. ANOTHER START ATTEMPT MADE ON NR 1 ENG. JUST PRIOR TO THE STARTER CUT OUT OF THE NR 1 ENG, L COWL A/I DUCT CAUTION MESSAGE BECAME EVIDENT. AT THE SAME TIME, STRONG ELECTRICAL ODOR . ENGINES SHUTDOWN & POWER REMOVED FROM THE ACFT. 3 POPPED CIRCUIT BREAKERS ON CPB2. FOUND EVIDENCE OF HIGH TEMP. ON CB`S & ASSOCIATED BUSS BAR DISCOLORED. NO DAMAGE NOTED TO WIRING OR ATTACHMENT LUGS, THE N3 CIRCUIT BREAKER SCREW FOUND LOOSE AT CB-N3 & BUSS BAR (NR250 AND NR255) INTERFACE.