What was found
(CAN) BURNED WIRES AT CONNECTOR FOUND ON ANNUAL INSP. WIRES WERE SPLICED TO INSTALL A AW10 IN PLACE OF A AWG12 AT THE WINDSHIELD DE ICE CONTROLLER. THIS WAS DONE BY SB30-006. THE IN LINE SPLICE WAS PN 971.31.32.604.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(CAN) BURNED WIRES AT CONNECTOR FOUND ON ANNUAL INSP. WIRES WERE SPLICED TO INSTALL A AW10 IN PLACE OF A AWG12 AT THE WINDSHIELD DE ICE CONTROLLER. THIS WAS DONE BY SB30-006. THE IN LINE SPLICE WAS PN 971.31.32.604.