Service difficulty report · Fire Loop · Propjt 200A

Difficulty date
July 23, 2009
Submitted
October 23, 2009
Operation
General aviation
Make and model
Propjt 200A
Aircraft time
1,149 hours
Engine
Pwc PW306A
Part
Fire Loop
Part number
7101771050
Condition
Failed
Location
Lt Engine
Part time
1,150 hours
Stage of operation
CL
How discovered
O
Nature of condition
P
Precautionary procedure
E, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ON CLIMB OUT AT APPROX 18,000 FEET, ACFT ROUTED ON EICAS THE PILOTS REPORTED THAT THE LT ENG FIRE DETECTOR INDICATED FAILED. PILOTS REPORTED THAT CHECK LIST HAD BEEN COMPLETED AND AS A PRECAUTIONARY MEASURE PROCEEDED TO SHUTDOWN ENG IN FLIGHT. ACFT WAS RE-ROUTED AND DECLARED AN EMERGENCY. TOWER REPORTED THAT NO FLAME OR SMOKE COULD BE SEEN FROM THE LT ENG. ACFT LANDED WITHOUT ANY OCCURRENCE. MX WAS CALLED TO INVESTIGATE AND FOUND THE FIRE LOOP IN ZONE 2 HAD FAILED. ZONE 2 FIRE LOOP WAS REPLACED AND CARRIED OUT FUNCTION CHECK ON SYS SERVICEABLE. WERE INFORMED OF THE FAILURE. PROBABLE CAUSE FOR FAILURE WAS IMPROPER CLAMPING AT THE END OF THE LOOP. NEW LOOP INSTALLED HAD THE LAST CLAMP, CLAMPED AT .250 INCHES FROM THE END OF THE LOOP WHICH LIMITS FREQUENCY VIBRATION. ACFT WAS GROUND RUN AND FUNCTION CHECK CARRIED OUT ON THE FIRE LOOP AND ALL SYS OPERATED SERVICEABLE. ACFT WAS RELEASED FOR RETURN TO SERVICE.