Service difficulty report · Pump · Bombdr BD1001A10

Difficulty date
August 7, 2009
Submitted
October 23, 2009
Operation
General aviation
Make and model
Bombdr BD1001A10
Part
Pump
Part number
9558057
Condition
Inoperative
Location
Hyd System
Stage of operation
TO
How discovered
O
Nature of condition
H
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED THEY HAD TAXIED OUT FOR TAKEOFF AND JUST PRIOR TO APPLYING TAKEOFF PWR AMBER CAS (L GEN FAIL) POSTED AND LT GENERATOR DROPPED OFF LINE. A FEW SECONDS LATER AMBER CAS (APU GEN FAIL) POSTED. CREW TAXIED BACK OFF THE RUNWAY. DURING TAXI, CREW NOTED CYAN CAS (R HYD DC PUMP FAIL) CYCLED ON. CREW TAXIED BACK AND SHUTDOWN THE ENGINES. CREW THEN NOTED THE C/B R DC PUMP C11 WAS TRIPPED. CREW RESET C/B AND TURNED ON THE RDCMP AND THE C/B POPPED AGAIN. THE RDCMP WAS REPLACED AND THE OPS CHECKS WERE GOOD ON THE GENERATORS.