What was found
(CAN) DURING CRUISE, WINDSHIELD HEAT SET TO NORMAL = SMOKE IN FLIGHT COMPARTMENT PROBLEM WINDSHIELD IDENTIFIED AND CIRCUIT ISOLATED. MAINTENANCE DISCOVERED 115 VAC POWER TERMINAL L1 & L2 NOT SECURED PROPERLY. (TC# 20090917001)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(CAN) DURING CRUISE, WINDSHIELD HEAT SET TO NORMAL = SMOKE IN FLIGHT COMPARTMENT PROBLEM WINDSHIELD IDENTIFIED AND CIRCUIT ISOLATED. MAINTENANCE DISCOVERED 115 VAC POWER TERMINAL L1 & L2 NOT SECURED PROPERLY. (TC# 20090917001)