What was found
(CAN) DURING FLIGHT, HYD PUMP EDP NR 2 FAILED. AFTER NORMAL LANDING PILOT WROTE: NR 2 ENG HYD PUMP U/S NR 2 RUD HYD CAUTION LIGHT ON ON GROUND NWS U/S WITHOUT ANY CAUTION. PERFORMED FLUSHING OF THE NR 2 HYD SYS IAW AMM TASK 29-10-00-617-803 TR 29-108. IN ADDITION TO FAILED EDP NR 2 PUMP PN 66173-03, SN K0538, REPLACED POWER TRANSFER UNIT PN 51149-04 SN K0251 AND NLG SOLENOID SEQUENCE VALVE PN 48302-5, SN FAH0754.