Service difficulty report · Support · Emb ERJ190100IGW

Difficulty date
October 4, 2009
Submitted
December 1, 2009
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
6,849 hours
Engine
Ge CF3410E5A1
Part
Support
Condition
Loose
Location
Mlg Ww Fire Loop
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) LT AND RT MAIN GEARBAY FIRE DETECTION LOOP SUPPORT STRUCTURE ADRIFT FROM AIRFRAME THREE OUT OF FOUR BONDED STRUCTURE BRACKETS HAVE DISBONDED FROM THE STRUCTURE. THE REMAINING THREE MECHANICALLY FASTENED BRACKETS AFIX THE ENTIRE FIRE DETECTION LOOP SUPPORT TO THE AIRFRAME. THIS CONDITION ALLOWS CONSIDERABLE MOVEMENT OF THE FIRE DETECTION LOOP/SUPPORT ASSY. POSSIBILITY OF DAMAGE DUE TO FATIGUE. STRUCTURE DEPT TECHS APPLIED ADHESIVE TO REBOND SUPPORT ASSY TO AIRFRAME. (TC 20091028002)