What was found
(CAN) LT AND RT MAIN GEARBAY FIRE DETECTION LOOP SUPPORT STRUCTURE ADRIFT FROM AIRFRAME THREE OUT OF FOUR BONDED STRUCTURE BRACKETS HAVE DISBONDED FROM THE STRUCTURE. THE REMAINING THREE MECHANICALLY FASTENED BRACKETS AFIX THE ENTIRE FIRE DETECTION LOOP SUPPORT TO THE AIRFRAME. THIS CONDITION ALLOWS CONSIDERABLE MOVEMENT OF THE FIRE DETECTION LOOP/SUPPORT ASSY. POSSIBILITY OF DAMAGE DUE TO FATIGUE. STRUCTURE DEPT TECHS APPLIED ADHESIVE TO REBOND SUPPORT ASSY TO AIRFRAME. (TC 20091028002)