What was found
(CAN) FLAPS FAULT - BROKEN RT INBD FLAP ACTUATOR FAIRING ROD. RECEIVED CALL STATING THAT THE CREW REPORTED A FLAPS FAULT AMBER MESSAGE IN FLIGHT. PILOTS SELECTED FLAPS 20 DURING APPROACH AND THE FLAP STOPPED AT 17 DEGS WHEN THE FLAP FAULT MESSAGE POSTED. UPON LANDING THE PILOTS ATTEMPTED TO MOVE THE FLAPS AND THE FLAPS OPERATED NORMALLY AND FAULT CLEARED. DURING INSPECTION IT WAS NOTED THAT THE RT INBD FLAP ACTUATOR FAIRING WAS NOT SECURED (REFERENCE ATTACHED PICTURES).