What was found
SMOKE COMING FROM 21 ABC SEAT ROW. SMOKE SOURCE FOUND TO BE LTV SEB AT ROW 21 ABC. SEB REMOVED IAW LTV AMM 44-00-00. LTV SYS C/B`S PULLED AND COLLARED. OPERATE IAW MEL 25-10-5. LIVE TV SYS INOPERATIVE. SEB PN 3042865-102, SN 11619, FURTHER ACTION SEB AT ROW 21L, VDU`S AT SEATBACK 21ABC, DPCU"S AT SEAT 21ABC, HEADPHONE JACKS AT 21ABC, VDU CABLE AT 21L, DPCU CABLE AT 21L, ZONE 3 FEED CABLE, SEAT TO SEAT CABLE AT 22L-21L REPLACED AND SYS TESTED SERVICEABLE IAW LTV AMM 44-20-28, PGE 5049, MEL CLEARED AND PLACARD REMOVED. SEB PT OFF/ON 3042865-102 SN OFF 11619, SN ON 0460. PT OFF/ON 702-01-100-003, PN 3042565-102, SN 11619 LTV INVESTIGATION FINDS THAT BAD BATCH OF KEMET CAPACITORS CAUSED ISSUE AND ISSUED SIL TO COVER AFFECTED UNITS. ISSUE CONSIDERED CLOSED.