What was found
CONTROLS FOR ELEV AND AILERON STIFFER THAN REST OF FLEET, SAME FROM EITHER CONTROL COLUMN. AILERON STIFF, MOVED TO DEFECT 920351 TO SPLIT SNAGS RECTIFICATION, PULLED PITCH AND ROLL DISCONNECT. FOUND PILOTS CONTROL COLUMN TO BE STIFF IN BOTH PITCH AND ROLL. ELEVATOR TO BE MAKING STRANGE NOISES WHEN MOVED BY HAND. LT ELEVATOR REMOVED IAW AMM 27-32-11, P 201, ITEMS 1-18. LT ELEVATOR ATTACHMENT BRGS (P/N-MS27648-16). R & R BEARINGS, PULL TESTED AND SEALED IAW AMM 20-19-02. LT ELEVATOR INSTALLED IAW 27-32-11 SECTION `B` AND FUNCTION CHECK COMPLETED. LT ELEVATOR INSTALLATION COMPLETED, FOUND SERVICEABLE.