What was found
(CAN) COMPLETION INSTALLED INTERIOR IN BAGGAGE BAY HAD A UPPER INTERCOSTAL INSTALLED THAT IS USED TO SUPPORT BAGGAGE BAY HEADLINER GROSS POINT PANELING. THE INTERCOSTAL INSTALLED WAS FOUND WITH EXCESSIVELY LONG SCREWS/BOLTS AND 1 SCREW/BOLT WAS FOUND CHAFING INTO THE GEN NR 1 POWER FEEDER CABLE SAA0001W-4. THE SCREW/BOLT HAD CAUSED DAMAGED TO THE INSULATION LAYERS OF THE CABLE, BUT DID NOT CONTACT THE CONDUCTOR. MFG ADVISED VIA SRPSA AND EO ISSUED TO CARRY OUT REPAIR.