Service difficulty report · Relief Valve · Cndair CL2151A10

Difficulty date
July 24, 2010
Submitted
January 4, 2011
Operation
Air carrier
Make and model
Cndair CL2151A10
Aircraft time
4,396 hours
Engine
Pwa CWASP
Propeller
Hamstd 43E60
Part
Relief Valve
Condition
Failed
Location
Hyd Pump
Component
Hydraulic Pump
Component part number
66WAL300
Stage of operation
FF
How discovered
O
Nature of condition
M, K, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHILE IN FLIGHT, COMING OFF A FOREST FIRE FIGHTING MISSION AND RETURNING TO BASE, THE PILOT SELECTED THE "WATER BOMBING SYS" OFF. THE CREW NOTICED A SPIKE (FLUCTUATIONS) ON THEIR HYD PRESSURE GAUGE TO AN ABNORMALLY HIGH 3850 PSI. THIS PRESSURE IS THE RELIEF VALVE SETTING FOR WHEN THE PUMP EXCEEDS ITS NORMALLY SET SYS PRESSURE OF 3000 PSI. OPERATING AT THE HIGH 3850 PRESSURE AND FLOW INCREASED THE TEMP OF THE HYD OIL TO THE POINT THAT IT MELTED THE PLASTIC SITE GLASS TUBE IN THE HYD RESERVOIR TANK. THIS RESULTED IN THE LEAKING OF HYD OIL FROM THE RESERVOIR TANK. THE ACFT LANDED IAW NORMAL LANDING PROCEDURES AND WAS TOWED OFF THE RUNWAY.