What was found
(CAN) DURING A INSPECTION, FOUND BUSHING (0712500-14) MISSING OUT OF HOUSING HINGE ASSY (PN 0712500-6), BUSHING HAD FALLEN OUT OF ASSY AND TRIM JACK, HINGE ASSY WAS ABLE TO MOVE VERTICALLY ON HINGE BUSHING. TRIM JACKS REMOVED, HOUSING ASSY REPLACED AND TRIM JACKS REINSTALLED.