Service difficulty report · Converter · Cndair CL6013A

Difficulty date
October 5, 2010
Submitted
January 4, 2011
Operation
Air carrier
Make and model
Cndair CL6013A
Aircraft time
8,924 hours
Engine
Ge CF348E5A1
Part
Converter
Part number
601509173
Condition
Failed
Location
Engine Monitor
Part time
29 hours
Component
Engine Monitor · Ge
Component part number
CMA73014
Stage of operation
CR
How discovered
O
Nature of condition
H
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CRUISE THE PILOT NOTICE THE AUXILIARY WARNING LIGHT WAS ON, ON THE ENG CONTROL PANEL, AN INDICATION OF POWER LOSS ON 1 CHANNEL, IN A DUAL CHANNEL SIGNAL DATA CONVERTER. ALL ENG INSTRUMENTS N1,N2, FF, ITT, FP, OP, & FUEL TOTALIZER GO THROUGH BOTH CHANNELS OF THE SIGNAL DATA CONVERTER. WHEN POWER IS LOST ON A CHANNEL ALL ENG INDICATION WILL REVERT TO BASIC REDUNDANT BACK UP SYS, VERT BARS ON 1 ENG AND DIGITS ON THE OTHER. EXAMPLE EA ENGINE INSTRUMENT HAS DUAL INDICATION A VERTICAL BAR AND DIGITAL. DURING THE ABOVE FLIGHT ALL ENGINES INDICATORS OPERATED NORMAL WHEN THE AUXILIARY WARNING LIGHT WAS ON. ACFT CONTINUED FLIGHT TO DESTINATION WITHOUT ANY ISSUES. UPON TROUBLESHOOTING THE SYS IT WAS FOUND THAT THE SIGNAL DATA CONVERTER WAS FAULTY ON CHANNEL NR 1. REPLACED SDC CONTROL BOX AND THE FAULT RECTIFIED. THE SDC WAS PREVIOUSLY REPLACED A FEW WEEKS EARLIER FOR ANOTHER FAULT. UPON FURTHER INVESTIGATION IT WAS FOUND THAT THE COMPONENT WAS REMOVED FROM ANOTHER ACFT FOR THE SAME IDENTICAL FAULT AND SENT TO THE SHOP FOR REPAIR. THE COMPONENT REPAIR BREAK DOWN REPORT DID NOT HAVE ANY INDICATION OF A PREVIOUS ISSUE THAT WAS FOUND, SIMPLY BENCH TESTED AND CERTIFIED.