Service difficulty report · Thermal Switch · Boeing 7377*

Difficulty date
January 6, 2011
Submitted
March 15, 2011
Operation
Air carrier
Make and model
Boeing 7377*
Aircraft time
15,641 hours
Part
Thermal Switch
Part number
G371J
Condition
Failed
Location
Hyd Pump
Part time
19,279 hours
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 2 ELEC HYD PMP OVERHEAT LIGHT ON DURING CLIMB. ELEC NR 2 OVERHEAT WARNING SW. FOUND FAULTY, SWITCH REPLACED IAW AMM 29-32-12. EMDP CASE DRAIN FILTER FOUND NO CONTAMINATION, LEAK CHECK CARRIED-OUT IAW AMM 29-11-41. OPS TESTED SERVICEABLE. P/N OFF: G37-1J S/N OFF: 30254 P/N ON: G37-1J S/N ON: 31318 FILTER P/N: 65-90305-58 B/N: 2360413.