Service difficulty report · Sensor · Cndair CL600*

Difficulty date
January 10, 2011
Submitted
March 15, 2011
Operation
Air carrier
Make and model
Cndair CL600*
Aircraft time
13,592 hours
Engine
Ge CF348C5
Part
Sensor
Condition
Failed
Location
Slat
Stage of operation
DE
How discovered
O
Nature of condition
F
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON APPROACH CREW RECEIVED A SLAT FAIL MESSAGE. SLATS DID NOT DEPLOY. CREW INITIALED A MISS APPROACH AND GOT THE ACFT SET UP FOR THE SLAT FAILURE. THEY LANDED WITH NO FURTHER ISSUES AND NO EMERGENCY WAS DECLARED. TRAX DEFECT 961864 IS OPEN AND MX STARTS TROUBLESHOOTING. THIS DEFECT WAS A RECURRING ISSUE FOR THAT REASON FLEET SPECIALIST AND MFG WAS INVOLVED WITH THIS DEFECT. 3 ACTION PLANS WERE COMPLETED AND MX FOUND THE 4 SLAT DISCONNECT SENSORS AT FAULT. ALL 4 SENSORS WERE SHORTED. 4 SLATS DISCONNECT SENSOR REPLACED AND SYS TEST SERVICEABLE. OPS TEST OF THE SLAT DISCONNECT SENSOR IS COMPLETED EVERY 6000 HRS ON TASK RJ9-27-900-117. THE NEXT DUE IS THE 9 APRIL 2011. LT OTBD SLAT DISCONNECT SENSOR PN:771409D, SN:M2015, TSN:15299 - CYCLE:7691 -TSO:15299 LT INBD SLAT DISCONNECT SENSOR, PN:771409D, SN:M2025, TSN:5173 - CYCLE:2826 - TSO:5173 RT OTBD SLAT DISCONNECT SENSOR, PN:771409D, SN:M2115,TSN:11684 - CYCLE:6139 -TSO:11684 RT INBD SLAT DISCONNECT SENSOR PN:771409D, SN:M2487, TSN:5173 - CYCLE:2826 -TSO:5173