Service difficulty report · Duct · Bombdr BD1001A10

Difficulty date
February 3, 2011
Submitted
March 15, 2011
Operation
Air carrier
Make and model
Bombdr BD1001A10
Aircraft time
1 hours
Engine
Hnywl AS90711A
Part
Duct
Condition
Failed
Location
Anti Ice System
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) CREW REPORTED THEY WERE DESCENDING WITH THE WING ANTI-ICE SYSTEM ON. THEY HEARD A LOUD POP AND RUSH OF AIR FOLLOWED BY THE RED ICAS (WING ANTI-ICE LEAK) POSTING. CREW FOLLOWED THE AFM. INSPECTED TAIL AND FOUND ANTI-ICE DUCT BLOWN APART. UNDER INVESTIGATION.