Service difficulty report · Volt Regulator · Bell 204B

Difficulty date
January 31, 2011
Submitted
September 9, 2011
Operation
Air carrier
Make and model
Bell 204B
Aircraft time
22,695 hours
Engine
Lyc T5311B
Part
Volt Regulator
Part number
CR2795B105A1
Condition
Failed
Location
Dc
Stage of operation
CR
How discovered
O
Nature of condition
B
Precautionary procedure
H, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CRUISE FLIGHT THE PILOT NOTICED THE AMMETER FLUCTUATE AND THE GENERATOR LIGHT FLICKER. THE PILOT BEGAN TO DESCEND WHEN THE GENERATOR LIGHT, LT BOOST PUMP LIGHT AND ROTOR RPM AUDIO ALL CAME ON AND THE COCKPIT BEGAN TO FILL WITH SMOKE. ALL UNNECESSARY SWITCHES WERE TURNED OFF AND THE ACFT LANDED SAFELY. INVESTIGATION IS ONGOING BUT IT IS SUSPECTED THAT THE VOLTAGE REGULATOR FAILED CAUSING A SEVERE OVER VOLTAGE CONDITION AND BOILING THE BATTERY. MARCH 8 2011 DISASSEMBLY OF THE VOLTAGE REGULATOR REVEALED THAT THE GLASS INSULATING TUBE PN 5759480P1 THAT CONTAINS THE CARBON PILE WAS NOT INSTALLED. THIS ALLOWED THE CARBON DISKS TO SHIFT AND MAKE CONTACT WITH THE ALUMINUM HSG BORE, LOWERING THE EFFECTIVE RESISTANCE OF THE PILE AND RESULTING IN UNREGULATED VOLTAGE. THE OVERVOLTAGE SENSING RELAY WAS DISASSEMBLED AND INSPECTED. A BROKEN SOLDER CONNECTION AND A BROKEN GLASS TUBE ENCASING THE LINEAR ACTUATOR WERE FOUND. THESE 2 DEFECTS RENDERED THE OVERVOLTAGE PROTECTION CIRCUIT UNSERVICEABLE. THE LID WAS REMOVED FROM THE BATTERY AND EVIDENCE OF OVERCHARGING AND VENTING COULD BE SEEN.

More about the Bell 204-B