Service difficulty report · Pump · Bombdr DHC8400

Difficulty date
February 28, 2011
Submitted
September 14, 2015
Operation
General aviation
Make and model
Bombdr DHC8400
Engine
Pwc PW150A
Propeller
Rotol CR4086123F17
Part
Pump
Part number
6617304
Condition
Failed
Location
Hyd System
Part time
5,039 hours
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) PILOTS REPORT: "NR 2 ENG HYD PUMP CAUTION LIGHT FLASHING. ASSOCIATED WITH CAUTION LIGHT WAS NR 2 SYS PRESSURE FLUCTUATING AND PTU PRESSURE. AFTER NOT MORE THAN 1 MINUTE OF FLASHING CAUTION LIGHT WAS STEADY WITH ASSOCIATED PTU PRESSURE BUT RN 2 SYSTEM PRESSURE STABLE AT 3000 PSI AND NO CHANGE IN NR 2 SYS QTY. QRH REFERENCED AND PARAMETERS MONITORED. AFTER 20 MINUTES CAUTION LIGHT WENT OUT AND NO FURTHER ADVERSE INDICATIONS. NORMAL APPROACH AND LANDING COMPLETED." NR 2 EDP REPLACED.