Service difficulty report · Wire · Cndair CL6002B19

Difficulty date
April 2, 2011
Submitted
September 14, 2015
Operation
General aviation
Make and model
Cndair CL6002B19
Part
Wire
Condition
Chafed
Stage of operation
AP
How discovered
O
Nature of condition
J, A, B
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ON APPROACH, THE CREW HAD A RT 10TH STAGE BLLED WARN MSG, RT JET PIPE WARN & THEN RT PACK HIGH PRESS. AFTER LANDING WITHOUT INCIDENT, THE CREW STARTED SMELLING SMOKE & SHUTDOWN THE ENG. AFTER THE ENG SHUTDOWN, SMOKE SMELL WENT AWAY. NR 2 ENG GEN POWER CABLES CHAFED ON NR 2 HYD LINE & SHORTER TO GND. ONCE THIS HAPPENED, THE SHORTING WIRE BURNT A HOLE IN THE HYD LINE, WHICH THEN IGNITED THE HYDRO FLUID. SEE SDR 2011041601516 & 2011040502326.