What was found
(CAN) THE SWITCH KEY WAY IS SUCH THAT THE CENTER TERMINAL IS VERY CLOSE TO STRUCTURE. THE INSULATING TAPE THAT WAS INSTALLED DETERIORATED ALLOWING THE SCREW HEAD TO CONTACT STRUCTURE AND SHORT OUT THE LANDING GEAR RELAY C/B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(CAN) THE SWITCH KEY WAY IS SUCH THAT THE CENTER TERMINAL IS VERY CLOSE TO STRUCTURE. THE INSULATING TAPE THAT WAS INSTALLED DETERIORATED ALLOWING THE SCREW HEAD TO CONTACT STRUCTURE AND SHORT OUT THE LANDING GEAR RELAY C/B.