Service difficulty report · Sensor · Airbus A321211

Difficulty date
April 16, 2011
Submitted
September 14, 2015
Operation
General aviation
Make and model
Airbus A321211
Aircraft time
26,252 hours
Engine
Cfmint CFM565B3P
Part
Sensor
Part number
B7280
Condition
Failed
Location
Pack Temp
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) FLIGHT DISPATCHED UNDER MEL 21-25-01 A1 NR 1 PACK INOPERATIVE. AFTER DEPARTURE, THE FLIGHT EXPERIENCE A NR 2 PACK FAILURE. A PHONE PATCH WAS ESTABLISHED WITH MAINTENANCE CONTROL AND A RESET WAS NOT ABLE TO BE ACCOMPLISHED. IN CONSULTATION WITH SOC, MAINTENANCE AND DISPATCH, THE FLIGHT ELECTED TO RETURN TO POINT OF DEPARTURE WHERE AN OVERWEIGHT LANDING OF APPROXIMATELY 10,000 KGS OCCURRED. P2 COMP OVERHEAT SENSOR 35HH FAULTED BY THE TEMP CONTROLLER. COMP OVERHEAT SENSOR 35HH REPLACED IAW AMM 21-61-12 PB401. PACK OPERATION CARRIED OUT. CHECKED SERVICEABLE. TEMP SENSOR, PN: B7280.