What was found
(CAN) DURING FLIGHT CREW PRE-FLIGHT TEST IT WAS OBSERVED THAT CAPTAIN`S, NR 1 STICK SHAKER WAS NOT OPERATING. MAINTENANCE TROUBLESHOOTING REVEALED A BROKEN WIRE IN WIRE BUNDLE REF W0145-0002-20 BROKEN AT GROUNDING TERMINAL GD41-DC. BROKEN WIRE REPAIRED AND OPS CHECK STATIS. NO FURTHER ISSUES. WDM REF. 27-32-11, PAGE 4/SHEET 2. STICK SHAKER MOTOR ASSY, IPC REF. 27-32-31-01, ITEM 36.