What was found
(CAN) DURING OPERATIONAL CHECK OF HYDRAULIC POWER TRANSFER UNIT SYSTEM,ARCING WAS OBSERVED AT WIRING BUNDLE CLAMP (APPROX) 2 FEET FROM RIGHT HAND ACMP POWER CONNECTOR. OPERATIONAL CHECK STOPPED , WIRING CLAMP REMOVED WHICH REVEALED CHAFFING AND ARCING OF RT ELECTRIC HYDRAULIC PUMP WIRES W228-001-8,W228-002-8,W228-003-8.