What was found
SLAT FAIL ON APPROACH TO RWY 05 AT 2000 FT, G/A INITIATED. PERFORMED QRH PROCEDURE, UNABLE TO CLEAR SLAT FAIL EICAS, SECOND APPROACH CONDUCTED TO RWY 05 IN SLAT 3/FLAP 2 MODE WITH 6000 FT. REQUIRED DISTANCE. CARRIED OUT FIM 27-81-00-810-807A. IAW AMM & SNL 170-27-0039. RT SKEW SENSORS 2-3 AND RT SKEW SENSOR 3-4 REPLACED IAW 27-83-01/401. RT HARNESS 2-3 REPLACED IAW 27-80-07/401. INHIBITS CLEARED. OPS TEST OF SLAT SYS COMPLETED IAW AMM 27-80-00-710-801-A/500.