Service difficulty report · Display

Difficulty date
May 26, 2011
Submitted
September 9, 2011
Operation
General aviation
Part
Display
Part number
100601702002
Part serial
028
Condition
Misoverhauled
Part time
21,930 hours
Stage of operation
IN
How discovered
V
Nature of condition
W
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RECENTLY RECEIVED A MCDU FOR REPAIR. WHILE CONDUCTING MX, NOTED THAT DURING A PREVIOUS REPAIR THAT SOMEONE HAD REPLACED A FUSE F1 ON THE 28 VOLT INPUT LINE OF THE LIGHTNING PROTECTION CIRCUIT BOARD WITH A SOLID WIRE. THE PRODUCT IS BEING REPAIRED AND BROUGHT BACK TO CONFORMITY AND DWG SPECIFICATION. NOTE: ADDED MAY 27 BY PRM: SUBSEQUENT EXPLANATION RECEIVED FROM AIRLINE, EXPLANING THAT THE CONDITION DETECTED WAS INDUCED DURING TROUBLESHOOTING PRIOR TO RETURNING THE UNIT TO CMC FOR REPAIR.