What was found
ECAM MESSAGE MLG NOT DOWNLOCKED, MANUAL GEAR EXTENSION, COMPLETED OVERSHOT & RECYCLED MLG. ON 2ND RECYCLE & WHILE IN TURN, MLG EXTENDED & LOCKED. TSM 32-31-00-810-857 CARRIED OUT & FOUND PROXIMITY SENSORS 33GA & 35GA OUT OF LIMITS. ADJUSTED IAW TSM 32-31-73-200-001. GEAR SWING CARRIED OUT SEVERAL TIMES WITH NO FAULTS.