What was found
EICAS C HYD QTY MESSAGE 4 HRS AFTER T/O. C HYD QTY SHOWED 0.46 TURNED OFF C HYD PRESS TO SAVE FLUID. QTY SLOWLY DROPPED TO 0.35. FRM 29-11-15-00. HYD LEAK FOUND AT C2 PUMP PRESSURE LINE. SEAL REPLACED AT PUMP UNION IAW AMM 29-11-02, PB401. LEAK CHECK OK. C HYD TANK SERVICED.