Service difficulty report · Contactor · Bombdr BD7001A10

Difficulty date
July 20, 2011
Submitted
September 9, 2011
Operation
Air carrier
Make and model
Bombdr BD7001A10
Aircraft time
1 hours
Engine
Rroyce BR700710A220
Part
Contactor
Part number
59117381
Condition
Burned
Stage of operation
IN
How discovered
O
Nature of condition
B, H
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

THE CREWS WERE ON GROUND JUST BEFORE DEPARTURE. THEY MOVED THE HYD PUMP 3A SWITCH TO ON TO PRESSURIZE SYS 3 TO USE PARKING BRAKE. WHEN THEY MOVED THE 3A SWITCH TO ON, THE CB FOR ASSOCIATED PUMP TRIPPED ON EMS CDU AND CAS MESSAGE HYD PUMP 3A FAILED APPEARED. SOME SECONDS AGO, THEY RESET THE CB AND IT TRIPPED AGAIN. SO THEY LEAVED THE CB TRIPPED AND THEY DEPARTED WITH PUMP 3A INOPERATIVE. HYD PUMP 3A WAS REPLACED WITH NO SUCCESS. HYD PUMP 3A FAILED CAS MESSAGE STILL POSTED ON THE EICAS. AFTER FURTHER TROUBLESHOOTING PERFORMED, THEY FOUND CONTACTOR K24 IN THE ACPC WITH SIGNS OF SHORT CIRCUIT. ACPC SHOWED ALSO SIGNS OF SHORT CIRCUIT. THE ACPC HAVE BEEN REPLACED AND WILL BE SENT TO MFG.