What was found
(CAN) DURING CLIMB SMOKE WAS SEEN COMING FROM FWD GALLEY COFFEEMAKER. COFFEEMAKERS TURNED OFF AND C/B PULLED. FOUND FWD GALLEY C/M 101B AT FAULT. TWO WIRES BURNED ON THE RESERVOIR ELEMENT. COFFEEMAKER REPLACED. CKD SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(CAN) DURING CLIMB SMOKE WAS SEEN COMING FROM FWD GALLEY COFFEEMAKER. COFFEEMAKERS TURNED OFF AND C/B PULLED. FOUND FWD GALLEY C/M 101B AT FAULT. TWO WIRES BURNED ON THE RESERVOIR ELEMENT. COFFEEMAKER REPLACED. CKD SERVICE.