Service difficulty report · Amplifier · Boeing 737*

Difficulty date
November 28, 2011
Submitted
September 14, 2015
Operation
General aviation
Make and model
Boeing 737*
Aircraft time
27,730 hours
Engine
Cfmint CFM567B27
Part
Amplifier
Part number
3042849101
Condition
Failed
Location
Rf Distributor
Stage of operation
CR
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) FLIGHT DIVERTED DUE SMOKE/FUMES REPORTED BY FLIGHT ATTENDANT. MAINTENANCE CARRIED OUT FIM 21-00 TASK 806(SMOKE OR FUMES IN THE CABIN, SOURCE UNKNOWN), HOWEVER NO FAULTS WERE FOUND. FIRE DEPARTMENT INSPECTED A/C WITH HEAT CAMERA UPON A/C ARRIVAL AND NO FAULTS WERE FOUND. AS A PRECAUTIONARY MEASURE THE LIVE TV SYSTEM WAS PLACED ON MEL PENDING A FULL LTV SYSTEM CHECK. AIRCRAFT RETURNED TO BASE AND ELECTRICAL ODOR SYS. INTEGRITY CHECK WAS STARTED BUT WAS UNABLE TO COMPLETE DUE TO NO VIDEO OR AUDIO IN CABIN. RDA WAS REPLACED BUT FAILED ON INSTALL. MEL REMAINED IN EFFECT. YYZ LIVE TV CONTINUED TROUBLESHOOTING: LTV RF DISTRIBUTOR AMPLIFIER WAS REPLACED I.A.W. LTV AMM 44-20-28. OPS CHECK SERVICEABLE. LTV ELECTRICAL ODOR SYSTEM INTEGRETY CHECK ACCOMPLISHED IAW LTV AMM 44-20-28. CHECK FOUND NO FAULTS.