Service difficulty report · Circuit Card · Bombdr BD7001A11

Difficulty date
January 10, 2012
Submitted
September 14, 2015
Operation
General aviation
Make and model
Bombdr BD7001A11
Engine
Rroyce BR700710A220
Part
Circuit Card
Part number
772707A
Condition
Burned
Location
Ac Power
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ELECTRICAL SYSTEM FAIL AND ELECTRICAL SYSTEM FAULT CAS POSTED ON THE GROUND WITH APU GEN ON-LINE. AC SYNOPTIC PAGE MISSES ALL FLOW LINES AND DC SYNOPTIC PAGE MISSES APU BATTERY INFO. FOLLOWING VISUAL INSPECTION OF SECONDARY SECTION OF THE ACPC, THERE WAS A NOTICEABLE ODOR OF BURNING AND CARD 10, 11 AND 12 SHOWED VISIBLE SIGNS OF ARCING. ALL CARDS OF THE LEFT ACPC WERE REMOVED AND INSPECT FOR FOREIGN DAMAGE. TWO AC SSPC CARDS (A23 AND A24 HAVE EVIDENCE OF BURN THROUGH. ALL OTHER CARDS WERE VISUALLY INSPECTED WITH NO OBVIOUS DAMAGE FOUND, THEY HAVE SIGNS OF CARBON BLACK ONLY.