What was found
(CAN) THE AME WAS PERFORMING A INTERNAL ZONAL INSPECTION OF THE CENTER WING SECTION FOR TASK RJ2-57-900-320 WHEN HE FOUND CRACKS EMINATING FROM EACH OF THE 2 RELIEF CUTOUTS FOR THE STRINGERS IN THE WEB OF THE SUPPORT ANGLE, PN: 601R10011-13 AND ANGLE PN:601R10011-14. THE ACFT IS CURRENTLY DOWN FOR A SCHEDULED "C" CHECK. REPAIR PARTS FABRICATED AND HEAT TREATED IAW SRM 51-10-06, SECTION 3D. ALUMINUM ALLOY FASTENERS INSTALLED IAW SRM 51-42-21 AND REPROTECTED IAW SRM 51-25-00 AND 51-25-16.