Service difficulty report · Sensor · Emb ERJ190100IGW

Difficulty date
February 14, 2012
Submitted
September 14, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
14,690 hours
Engine
Ge CF3410E5A1
Part
Sensor
Condition
Failed
Location
Slat Skew
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
L

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) SLATS FAILED IN THE FULL POSITION. GO-AROUND INITIATED DUE UNSTABLE APPROACH. FLIGHT DECLARED EMERGENCY. SLAT FAIL CAUTION ON SHORT FINAL, SLAT FULL/FLAP 5 WHEN CAUTION, SLAT FULL/FLAP 2 FINAL LANDING CONFIG, DUE NO FLAP THREE AVAIL ON FINAL. REPLACED DEFECTIVE SLAT/SKEW SENSOR BETWEEN SLATS 3 AND 4 ON RT OTBD WING IAW AMM 27-83-01, PB 401. OPS TEST SERVICABLE. SLATS/FLAPS CYCLED SEVERAL TIMES WITH NO FAULTS.