Service difficulty report · Hose · Cndair CL604

Difficulty date
February 19, 2012
Submitted
September 14, 2015
Operation
General aviation
Make and model
Cndair CL604
Part
Hose
Part number
QDCOUPLING
Condition
Leaking
Location
Hyd System
Stage of operation
CR
How discovered
O
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) WAS FLYING WHEN THE FLIGHT CREW REPORTED THAT THE AMBER HYD 2 LO PRESS MSG ILLUMINATED ON THE ENG INDICATION & CREW ALERTING SYS, EICAS. THEY ACCESSED THE HYD SYNOPTIC PAGE & NOTED THAT THE HYD SYS NR 2 QTY DECREASED TO 0% IN A RELATIVELY SHORT PERIOD OF TIME & THE RT EDP 2A WAS AMBER. FOLLOWED CHECKLIST, DIVERTED & DECLARED AN EMER. NOTED THE NR 2 HYD SYS RAN DRY FOR APPROX 40 MINUTES. AFTER LANDING, CARRIED OUT A VISUAL INSPECTION AROUND THE ACFT & NOTICED FLUID DRIPPING OUT OF THE RT ENG NACELLE DRAIN. THE HYD FLUID LEAK WAS EMANATING FROM THE RT EDP PRESS FLEX HOSE QUICK DISCONNECT COUPLING AT THE ATTACH BRACKET. SEE ALSO SDR 2012031700790 J7SA20120219001.