Service difficulty report · Sensor · Emb ERJ190100IGW

Difficulty date
March 3, 2012
Submitted
September 14, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
12,159 hours
Engine
Ge CF3410E5A1
Part
Sensor
Condition
Failed
Location
Cabin Pressure
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) FLIGHT DEPARTED UNDER MEL FOR ONE BLEED INOPERATIVE. AFTER DEPARTURE THE FLIGHT CREW REPORTED BEING UNABLE TO PRESSURIZE THE ACFT. THE FLIGHT RETURNED. NO EMERGENCY DECLARED NR 2 BLEED REPLACED BLEED TEMP SENSOR IAW AMM 36-14-03. ENGINE PNUEMATIC BLEED SYS TEST CARRIED OUT IAW AMM TASK 36-11-00-710-801-A.