What was found
(CAN) THE AME WAS PERFORMING AN INTERNAL ZONAL INSPECTION OF THE CENTER WING SECTION FOR TASK RJ2-57-900-320, WHEN HE FOUND CRACKS EMINATING FROM EACH OF THE 2 RELIEF CUTOUTS FOR THE STRINGERS IN THE WEB OF THE SUPPORT ANGLE. PN: 601R10011-13 AND ANGLES, PN:601R10011-14. THE ACFT IS CURRENTLY DOWN FOR A SCHEDULED, C-CHECK. REPAIR PARTS FABRICATED AND HEAT TREATED IAW SRM 51-10-06, SECT 3D. ALUMINUM ALLOY FASTENERS INSTALLED IAW SRM 51-42-21 AND REPROTECTED IAW SRM 51-25-00 AND 51-25-16.