What was found
(CAN) DURING CLIMB, THE FLIGHT CREW REPORTED A LOUD SQUEAL AROUND THE R1 DOOR AREA. FURTHER INSPECTION BY CREW REVEALED A VISIBLE .1250-.2500" HOLE LOCATED AT THE BOTTOM LEFT OF THE PRESSURIZATION SEAL ON THE R1 DOOR. THE FLIGHT CREW THEN ELECTED TO PERFORM AN AIR TURNBACK AND RETURN FOR MAINTENANCE. MAINTENANCE INVESTIGATION DISCOVERED THAT THE R1 DOOR SEAL WAS IN FACT SERVICEABLE IAW AMM 52-09-12. FURTHER INSPECTION DISCOVERED THE R1 FORWARD LOWER FASTENER RECESS SEALANT TO HAVE FAILED CAUSING THE SQUEAL. NEW SEALANT, PN 5522352411, BN 2513535 WAS APPLIED IAW AMM 53-11-02 AND THE ACFT WAS THEN RETURNED TO SERVICE.