Service difficulty report · Control Panel · Emb ERJ190100IGW

Difficulty date
May 20, 2012
Submitted
September 14, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
13,935 hours
Engine
Ge CF3410E5A1
Part
Control Panel
Part number
17000628409
Condition
Failed
Location
Elevators
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) CREW LOST THE STANDBY ACTUATOR FOR ELEVATOR CONTROL. INDICATOR WAS FLASHING ON AND OFF REVERSE YELLOW. ORIGINALLY LOST BOTH ELEVATOR SYS. NORMAL MODE WAS REESTABLISHED A SHORT TIME LATER. EICAS MSG ELEVATOR FAULT IN FLT. RESET C/O. SYSTEM RETURNED TO NORMAL BUT STBY ACTUATOR ELEVATOR FLASHING YELLOW. REF FAULT CODE 27030319FCS- FIM 27-03-00-810-88TA. FCP REPLACED IAW IAW AMM 27-03-01PB401. OPS TESTED SERVICE.