Service difficulty report · Circuit Card · Bombdr BD1001A10

Difficulty date
June 15, 2012
Submitted
September 14, 2015
Operation
General aviation
Make and model
Bombdr BD1001A10
Engine
Hnywl AS90711A
Part
Circuit Card
Part number
355CE03Y05
Condition
Failed
Stage of operation
CR
How discovered
O
Nature of condition
H
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) WHILE IN CRUISE, THE FLIGHT CREW HAD A RT DC PUMP CB TRIP FOLLOWED BY A LT BATTERY FAIL CAS MSG & AN ELEC FAULT MSG. THE LT BATTERY WAS SHOWING 27.5 VOLTS & 5 MINUTES LATER THE LT AUX BUS FAIL CAS MSG WAS POSTED. THE ACFT WAS WITHIN RANGE TO DESTINATION & BEGAN ITS DESCENT AT AROUND 20,000 FT. THE APU WAS STARTED & ALL FOUR COCKPIT FLIGHT DISPLAYS LOST ELEC POWER. THE COPILOT FLIGHT DISPLAY PFD 2 & THE PILOTS MULTI-FUNCTION DISPLAY MFD 1 WAS RECOVERED. THE ACFT LANDED UNEVENTFULLY WITH ANOMALIES ON THE ELEC SYS & BLANK FLIGHT DISPLAYS. AT THE GATE, THE FOLLOWING ISSUES WERE STILL PRESENT, LT PFD BLANK, LT MAIN BUS FAIL, FD 1 FAIL & BATTERY FAIL. DURING TROUBLESHOOTING FOUND THE LT PROTECTION CARD FAILED, FOUND IN MDC, AFTER SWAP WITH THE RT CARD, FAULT WENT TO OTHER SIDE NOW. REPLACED LT DCPC PROTECTION PCB. INSPECTED RT DCMP & CONTACTOR FOUND OK, MEASURED RESISTANCE FOUND OK. OPERATED RT DCMP WITHOUT PROBLEMS. ACFT RETURNED TO SERVICE.