Service difficulty report · Valve · Emb ERJ190100IGW

Difficulty date
August 4, 2012
Submitted
September 14, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Engine
Ge CF3410E5A1
Part
Valve
Part number
10070865
Part serial
2007100473
Condition
Failed
Location
Fan Air
Part time
124 hours
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) FLIGHT WAS DISPATCHED WITH MEL 36-11-09A LT BLEED AIR FAN VALVE OPEN WHICH INCURS 36-00-00-A1 BLEED 1 INOPERATIVE. ENROUTE, FLIGHT EXPERIENCED A BLEED 2 LEAK WHICH RESULTED IN LOSS OF PRESSURIZATION. THE FLIGHT DECLARED AN EMERGENCY AND DESCENDED TO 9000 FT. THE CABIN PRESSURE DID NOT EXCEED 9500 FT SO O2 MASKS DID NOT DEPLOY. THE FLIGHT CONTINUED WITH PRIORITY HANDLING ARRANGED WITH ATC. AFTER A NORMAL LANDING, THE AIRPORT WENT ONTO RED ALERT RESULTING IN THE ACFT SELF PARKING AT THE GATE AS A RESULT OF THE RISING TEMPERATURES IN THE CABIN CAUSING PASSENGER DISCOMFORT WITH NO AIR CONDITIONING AVAILABLE AS A RESULT OF THE FAILURE. NR 1 FAN AIR VALVE REPLACED IAW AMM 36-11-09-400-801.