Service difficulty report · Wire · Bell 407

Difficulty date
May 18, 2012
Submitted
September 14, 2015
Operation
General aviation
Make and model
Bell 407
Engine
Allsn 250C47B
Part
Wire
Part number
407375007107
Condition
Damaged
Location
Fuel Pressure
Part time
93 hours
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) THE FUEL PRESSURE INDICATION WOULD GO TO 1 OR NO BARS INDICATED. THIS REQUIRED A TERMINATION OF ANY PATIENT FLIGHTS AND RETURN TO BASE MULTIPLE TIMES. THE SYSTEM SEEMED TO CHECK OUT PROPERLY WHEN MAINTENANCE SHOWED UP. EVENTUALLY, PN 407-375-007-107 INDICATOR WAS R & R AND THE SYSTEM WORKED PROPERLY. THE INDICATOR WAS INSTALLED IN ANOTHER ACFT AND WORKED PROPERLY. WHEN REINSTALLED BACK IN THE ORIGINAL ACFT AFTER A FEW HOURS THE SYS FAILED AGAIN. AT THAT TIME THE WIRE FROM PIN 3, E548A22 OF CONNECTOR 2M1P1, 10VDC POWER TO THE TRANSDUCER, WAS FOUND WITH VERY THIN LAYER OF INSULATION AND SHORTING TO THE CONNECTOR AND SHIELD. THIS WAS REPAIRED AND THE SYS PUT BACK IN SERVICE. AFTER 2 HOURS, THE SYSTEM FAILED AGAIN. THIS TIME THE INSTRUMENT WOULD NOT WORK IN ANOTHER ACFT. EVIDENTLY, THE HIGH CURRENT LOADS WITH THE PREVIOUS SHORT CIRCUIT CAUSED THE POWER SUPPLY TO FAIL. NEW GAUGE REMEDIED THE PROBLEM. ROOT CAUSE INVESTIGATION HAS REVEALED THIN INSULATION ON THE WIRING OF THE FUEL PRESSURE TRANSDUCER THAT HAS CAUSED SHORTING TO THE CONNECTOR. QA HAS BEEN ADVISED TO BETTER CONTROL THE MFG PROCESS OF THESE WIRES.