Service difficulty report · Generator · Bombdr DHC8400

Difficulty date
November 8, 2012
Submitted
September 14, 2015
Operation
General aviation
Make and model
Bombdr DHC8400
Engine
Pwc PW150A
Part
Generator
Part number
11522185
Condition
Malfunctioned
Location
Nr 2 Ac
Part time
6,300 hours
Stage of operation
CL
How discovered
O
Nature of condition
K, J
Precautionary procedure
E, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING TAKE OFF, AN OPERATOR HAD A NR 2 AC GENERATOR CAUTION FOLLOWED BY A NR 2 AC GENERATOR HOT CAUTION LIGHT. THE AC GENERATOR WAS SELECTED OFF. PILOT THEN NOTICED A NR 2 OIL LOW PRESSURE WARNING AND VERIFIED THAT THE OIL PRESSURE GAUGE WAS REDUCING TOWARD ZERO PSI. THE NR 2 ENGINE WAS SHUT DOWN. DURING THE SHUT DOWN PROCEDURE THE NO.2 PEC CAUTION ILLUMINATED AND THE NO.2 PROP DID NOT FEATHER. NR 2 ALTERNATE FEATHER COMPLETED AND PROPELLER FEATHERED. AIRCRAFT RETURNED TO BASE WITH NR 2 ENGINE SHUT DOWN. LANDING WAS UNEVENTFUL. ENGINEERS ADVISE THE ENGINE OIL SIGHT GLASS IS EMPTY. SUSPECT OIL DID NOT SCAVENGE BACK AND REMAINS IN THE RGB.