Service difficulty report · Coupling · Boeing 7378Q8

Difficulty date
January 22, 2013
Submitted
September 14, 2015
Operation
General aviation
Make and model
Boeing 7378Q8
Aircraft time
18,516 hours
Engine
Cfmint CFM567B26US
Part
Coupling
Part number
W994BF08DE
Condition
Leaking
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING FLIGHT THROUGH 35,000 FT. THE CREW FOUND THE PRESSURIZATION TO BE FLUCTUATING AND THE OUTFLOW VALVE TO BE UNRESPONSIVE. DURING A DESCENT TO SEE IF THE ISSUE WOULD BE RESOLVED, THE OUTFLOW VALVE WENT TO FULL OPEN AND THE ACFT DECOMPRESSED. THE CREW INITIATED A RAPID DECENT AND OXYGEN WAS DEPLOYED TO THE CREW AND PASSENGERS. THE ACFT RETURNED TO ITS ORIGIN AND LANDED WITHOUT ANY FURTHER ISSUES. THERE WERE NO REPORTED INJURIES TO CREW OR PASSENGERS. AFTER ARRIVAL, MAINTENANCE INSPECTED THE ACFT AND IMMEDIATELY FOUND SUBSTANTIAL ICE AROUND AND IN THE OUTFLOW VALVE. THIS ICE WOULD HAVE RESTRICTED THE MOVEMENT AND CONTROL OF THE VALVE. IN ADDITION TO THE OUTFLOW VALVE, ADDITIONAL ICE WAS FOUND AROUND THE DRAINS AND TAIL SKID. FURTHER INSPECTION REVEALED THAT A POTABLE WATER COUPLING HAD RELEASED IN THE AFT SECTION OF THE ACFT. THIS CAUSED POTABLE WATER TO BE SPRAYED DIRECTLY ONTO THE OUTFLOW VALVE FROM THE INSIDE OF THE ACFT. THE REASON FOR THE COUPLING RELEASE IS DUE TO A FROZEN WATER LINE. UPON REVIEW OF THIS FAILURE WE DISCOVERED IT IS A KNOWN ISSUE WITH THIS MODEL ACFT AND HAS PUBLISHED THE ATTACHED FLEET TEAM ARTICLE. WE ARE REVIEWING OUR COLD WEATHER GROUND HANDLING PRACTICES TO ENSURE THEY ARE SUFFICIENT AND FOLLOWED PROPERLY.

More about the Boeing 737-8Q8