What was found
(CAN) DURING MAINTENANCE INSPECTION, CHAFING WAS DISCOVERED ON THE SPIRAL ELECTRICAL CORD LOCATED IN THE INBD TELESCOPIC DUCT OF THE LT WING L/E. THE SAME WAS FOUND AT THE INBD AND OTBD RT WING L/E LOCATIONS. THE CHAFED SPIRAL CORDS WILL BE REPLACED IAW CMM 30-11-07.