Service difficulty report · Circuit Board · Bombdr BD1001A10

Difficulty date
March 13, 2013
Submitted
September 14, 2015
Operation
General aviation
Make and model
Bombdr BD1001A10
Engine
Hnywl AS90711A
Part
Circuit Board
Part number
716CE03Y01
Condition
Damaged
Location
Battery
Part time
70 hours
Stage of operation
TX
How discovered
O
Nature of condition
H, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) THIS IS A PARTS RELIABILITY ISSUE AND HAS OCCURED TWICE SINCE JANUARY 28, 2013. JANUARY 28, 2013, LT BATTERY WILL NOT CONNECT TO BUS, INDICATES 26.5V. REMOVED LDCPC BATTERY DIODE CIRCUIT AND INSTALLED INSPECTED PC BOARD IAW AMM 24-61-82, PERFORMED OPS TEST OF BATTERY BUS CONTACTOR IAW AMM 24-61-05 AND BUS TIE CONTACTOR IAW AMM 24-61-29 WITH NO DEFECTS NOTED. DETAILS ON FILE WO 163100. LOANER BATTERY DIODE CURCUIT BOARD, PN 716CE03Y01, SN 348, INSTALLED IN LT DCPC, REFER TO MAINTENANCE LOG 106204. LOANER BATTERY DIODE CIRCUIT BOARD REMOVED SERVICEABLE AND NEW CIRCUIT BOARD INSTALLED IAW AMM TASK 24-61-82-400-801. OPS TESTS SERVICEABLE. LEFT BATTERY WILL NOT TURN ON WHEN SELECTED REPLACED LT BATTERY DIODE CIRCUIT BOARD WITH A REMOVED SERVICEABLE CIRCUIT BOARD IAW AMM TASK 24-61-82-400-801. OPS TESTS SERVICEABLE.