Service difficulty report · Generator · Bombdr BD7001A10

Difficulty date
April 4, 2013
Submitted
September 14, 2015
Operation
General aviation
Make and model
Bombdr BD7001A10
Aircraft time
1 hours
Engine
Rroyce BR700710A220
Part
Generator
Part number
GL51111035
Condition
Failed
Location
Nr 1
Part time
1,744 hours
Stage of operation
CR
How discovered
O
Nature of condition
H, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING THE CRUISE, A CYAN GEN 1 FAIL CAPTION WAS SEEN ON THE CAS. THE AC ELECTRICAL SYNOPTIC PAGE CONFIRMED A GENERATOR 1 FAIL. THE QRH GEN 1 FAIL DRILL WAS ACTIONED, HOWEVER THE GENERATOR WAS NOT RECOVERED. GENERATOR 1 WAS THEN SELECTED OFF AND THE ACFT RECOVERED TOWARDS BASE. APPROXIMATELY 5 MINUTES LATER A BANG WAS HEARD BY THE CREW IN THE CABIN AND A SHUDDER FELT THROUGH THE AIRFRAME. THE ACFT LANDED AT BASE WITHOUT FURTHER INCIDENT. THE ACFT WAS SEEN-IN AND SHUTDOWN STANDARD PRACTICES. IMMEDIATELY NOTICEABLE WAS A 300 X 200 MM HOLE IN THE LT LOWER COWLING, BELOW VFG NR 1. ON OPENING THE COWL THE OIL SUMP WAS FOUND TO BE CRACKED WITH SEVERAL PARTS MISSING. THE VFG OIL SUMP/RESERVOIR HAD EXPERIENCED A STRUCTURAL FAILURE AND THE RESULTANT DEBRIS PUNCTURED THE COWL.