Service difficulty report · Acm · Emb ERJ190100IGW

Difficulty date
April 27, 2013
Submitted
September 14, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
16,172 hours
Engine
Ge CF3410E5A1
Part
Acm
Part number
10007005
Condition
Failed
Location
Left
Stage of operation
TO
How discovered
O
Nature of condition
B
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) APPLIED T/O POWER DEPARTING AT APPROXIMATELY 60KTS-70KTS THERE WAS VISIBLE WHITE SMOKE FROM FROM GASPERS, CREW REJECTED T/O. SMOKE CLEARED AFTER THE REJECT. ACFT WAS MET AND ESCORTED BACK TO GATE WITHOUT FURTHER INCIDENT. LT PACK REMOVED INSPECTED HEAT EXCHANGERS NO FAULTS, POSSIBLE LT ACM AT FAULT. NR 1 LT ACM CHANGED IAW AMM 21-50-00. LEAK CHECK AND FUNCTIONAL TEST CARRIED OUT. ENGINE RUN TO 82 PERCENT N1. NO OR MINIMAL RESIDUAL ODOR.

More about the Emb ERJ 190-100 IGW